My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
95-5176
Zephyrhills
>
Building Department
>
Permits
>
1995
>
95-5176
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 2:40:09 PM
Creation date
6/29/2006 8:58:13 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
95-5176
Building Department - Name
FRIST UNION
Address
38421 5TH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />. - <br />EEl ! 55a:__-_E:~~~5U <br />....j.~..~..i~~~ <br /> <br />~ <br /> <br />OPTIONAL <br />SHOE BOX <br />BRACKET <br /> <br />,REMOVABLE TOP CAP <br />- -;::-;. ----..,,"--~--.;? <br /> <br />.-----'. <br />'..___-,__Jo <br /> <br /> <br />OPTIONAL TAPERED OVAL ALUMINUM <br />MAST ARMS AVAILABLE IN 4 AND 6 FT, <br />LENGTHS <br /> <br />STEEL ~' , <br />TENON <br />OPTIONAL <br /> <br /> <br />STANDARD 21/2' x 5" HANDHOLE WITH <br />CAST ALUMINUM COVER. HANDHOLE <br />AREA REINFORCED FOR ADDED <br />STRENGTH. <br /> <br />STANDARD WIRE ENTRY <br /> <br />SQUARE DIRECT BURIAL BASE <br />FOR ANTI'ROTATION <br /> <br />POLE SIZES <br /> <br />The Series E35 standard duty and Series E36 heavy duty <br />poles are available in overall shaft lengths of 15 It, to 35 It, <br /> <br />OPTIONAL POLE TOP TENON SIZES -- <br /> TENON OUTSIDE INSIDE <br /> LENGTH DIMENSIONS DIMENSIONS <br /> -- <br />~!'ONAL EXTRA COST 3W' 3- 2V." <br />OPTIONAL EXTRA COST 3W' 2Vo" 2" <br />OPTIONAL EXTRA COST 3'h" 3" 2V,' <br />OPTIONAL EXTRA COST 3'17- 4' 3W' <br /> <br />STEEL SHOE BOX BRACKET SIZES <br />OPTIONAL EXTRA COST 2- N.P,S. (2Vo- 0,0.) <br />OPTIONAL EXTRA COST 1 v.- N.P.S, (1 y." 0.0,) <br /> <br />HANDHOLE SIZES <br /> <br />STANDARD <br />OPTIONAL REDUCED COST <br /> <br />2'f.( x 5" OVAL <br />----~ <br />2'17- ROUND <br /> <br />STANDARD <br />OPTIONAL SIZES <br /> <br />WIRE ENTRY HOLE SIZES <br />2" x 5" <br />----~~- <br />AVAILABLE UPON REQUEST <br /> <br />STANDARD SPECIFICATIONS <br />ROUND TAPERED FIBERGLASS <br />SERIES E35 AND E36 <br /> <br />1. General Description <br />1,1 Fiberglass lighting pole to be round. hollow, and of <br />uniform taper along its length. The butt end of the embed- <br />ded-type poles will be enlarged and square so as to in- <br />crease resistance to rotation and provide maximum ground <br />bearing resistance (anti-lift!. The pole shall be non-conduc- <br />tive and chemically inert. <br /> <br />2. Installation Data <br />2.1 Direct embedded poles from 15 ft. to 17 ft. will be <br />set to a depth of 3 ft. Direct embedded poles 18 ft. to 29 <br />ft. will be set to a depth of 4 ft. Poles 30 ft. or more will <br />be set to a depth of 5 ft. <br /> <br />3. Pole Shaft Construction <br />3.1 The pole will be constructed from continuous fiber- <br />glass filaments combined with thermosetting polyester <br />resin. <br />3.2 The fiberglass and resin ratio of the pole will contain <br />at least 65 % glass, the balance polyester resin. <br />3,3 The glass filament will be helically-wound under <br />tension, first at a relatively high angle (65-85 degrees) to <br />the longitudinal axis of the pole. with alternate layers of <br />filaments in opposite directions for maximum circum- <br />ferential (compressive) strength. <br />Secondly, an outer core section of greater weight than the <br />inner core section is helically-wound by wrapping continu- <br />ous glass filaments at a relatively low angle (3-15 degrees) <br />to the longitudinal axis of the pole for maximum longitudi- <br />'1 (bending) strength. <br />,4 The pole shall have a minimum wall thickness of 3/32 <br />In. The pole shall have a tapered wall increasing in thick- <br />ness from the top to base in proportion to the load and <br />ground line moment requirements. The pole will be rein- <br /> <br />forced in areas of hand holes and special hardware attach- <br />ments. <br />3.5 The pole shall be designed with a minimum safety <br />factor of 2 to 1 and have no more than 15 % deflection at <br />full wind loading. <br /> <br />4. Pole Top <br />4.1 Tenon Style: A steel tenon will be firmly bonded to <br />the pole for mounting a post top luminaire. The steel tenon <br />will be straight with no taper. The tenon will be coated <br />with matching urethane finish. <br />4.2 Bracket Style: The pole shall be capped (optional) and <br />reinforced for side mounted bolt-on brackets. <br /> <br />5. Handhole <br />5.1 The handhole shall be 2% in. x 5 in. oval, located 18 <br />in. above grade. The cover shall be non-corrosive metal <br />painted to match the pole and secured with a stainless <br />steel, tamper-proof locking screw. <br /> <br />6. Wire Entrance <br />6.1 The pole shall have a wire entrance hole of 2 in. x 5 <br />in. located 24 in. below grade, 900 clockwise to luminaire. <br /> <br />7. Finish <br />7.1 The surface of the pole shall be uniform and consis- <br />tent for the entire length of the pole. <br />7.2 The resin shall contain colored pigment to match the <br />finish coat of the pole. Solid coloration will be throughout <br />the entire wall thickness of the pole. <br />7.3 The finish coating will be a pigmented urethane finish <br />capable of withstanding exposure to ultraviolet, chemicals, <br />and extreme weather conditions. <br />7.4 The surface coating shall be a minimum dry film <br />thickness of 1 Y, mils. <br />
The URL can be used to link to this page
Your browser does not support the video tag.