Laserfiche WebLink
<br />2. Fuse and reset: 2001-2085 <br />3. Zone, box circuits (No. per zoning sched.): 2001-1019 <br />4. March time coder (Dual rate): 1001-3044 <br />5. Signal circuit modules: 2001-2076 <br />6. Internal transformers: 2001-3058 <br />7. Reverse polarity module(24-volt D.C.): 2001-2039 <br />8. Power supply: 2001-3021 <br />9. Auxiliary relay: 2001-3006 <br />10. Sprinkler Supervisory Module: 2001-3006 <br />11. Sprinkler Supervisory Signal Circ. Module: 2001-2075 <br />12. Battery Monitor Module: 2001-2067 <br />13. Battery Charger Module: 2001-3002 <br />14. Battery (as required): 2001-3071 thru 2001-3074 <br />15. Single action break glass station(with ann. cont): 2099-9209 <br />16. Clg. Smoke detector (light refract): 2098-9642 (Furnish 2908-9536 base when aux. <br />relay is required)with 9637 base <br />17. Clg. smoke detector (Ionization): 2908-9544 (Furnish 2908-9536 base when aux. <br />relay is required) with 9637 base <br />18. Door holder (wall mounted): 2088-9554 <br />19. Chime/light combination (Xenon strobe): 2902-9042/4903-9101 <br />20. 2903-9006Horn/light combination (Xenon strobe): 2901-9833/4903- <br />21. Flashing light (Xenon strobe): 4904-9101 <br />22. Provide Visual Strobe appliances in accordance with ADA criteria. The minimum <br />flash rate shall be at least 1 Hz( 60 flashes per minute) and the maximum flash rate <br />shall not exceed 2Hz(120 flashes per minute). <br />23. Visual Strobes flash rates shall be synchronized wherever flashes from multiple <br />strobes may be visible from one location. <br />24. End of line devices: as required <br /> <br />C. Zone annunciator per zoning schedule on drawings and include: lamp test switch, <br />amber trouble light, keyed trouble reset switch, trouble buzzer, keyed trouble silencing <br />switch. Provide plug-in type incandescent or LED lamps. <br /> <br />D. Provide box circuit modules with a disconnect switch for each circuit where more than <br />one circuit is served by a single P.C. board module. Where each plug-in module ofP.C. <br />board serves only one circuit and can be removed without disturbing other circuits, the <br />disconnect switch provision is not required. <br /> <br />E. Provide special lettering on stand-alone flashing lights. V erticallettering on rectangular <br />faces and horizontal on triangular faces when lights are ceiling mounted. <br /> <br />F. Where dry pipe sprink~er system(s) are utilized, wire and connect separate waterflow <br />switch(es), valve tamp~r switch(es) and pressure sensor(s) that monitor high and low <br />pressure conditions in $ccordance with NFP A-72 requirements. <br /> <br />July 12,2000 <br />November 22, 2000 <br /> <br />16721 - 3 <br /> <br />99087.00 <br />Revision No.5 <br />