My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
01-0090
Zephyrhills
>
Building Department
>
Permits
>
2001
>
01-0090
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:43:29 PM
Creation date
10/12/2006 8:34:41 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
01-0090
Building Department - Name
E P M C
Address
GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />PART - 3 EXECUTION <br /> <br />3.01 INSTALLATION <br /> <br />A. Provide modifications to existing system complete and in accordance with <br />manufacturer's in~tructions, including conduit, boxes, wiring and accessories. Install all <br />fire alarm system wiring in "EMT" conduit. Tag wires at junction points. Provide #14 <br />wire for all devices except AIV units which will be # 12 type THHN/THWN. Provide <br />all fire alarm wiring color coded per manufacturer's recommendations. Refer to section <br />16120, article 3.10 (2) for additional restrictions on fire alarm system wiring. <br /> <br />B. Provide (at no cost) on-premises maintenance during normal working hours for a <br />period of twelve months from date of final approval. <br /> <br />c. Supplier to have been in business for a minimum of five years and have a <br />representative available on a 24-hour basis within 100 miles of the subjectjobsite with <br />letter of reference to this affect being included in submittals. <br /> <br />D. Provide Owner's maintenance personnel a minimum of two instruction sessions by a <br />factory-trained technician for operation and maintenance of system. Provide factory- <br />trained technician available for testing of existing system. <br /> <br />E. Provide 190 deg F. fixed temperature heat detectors in mechanical rooms and 135 deg <br />F. fixed temperature and rate of rise heat detectors in all other areas where heat <br />detectors are shown on drawings. <br /> <br />F. Wire initiation devices utilizing class liB ", two-wire, fully supervised circuits to end of <br />line device located after the last initiation device. Initiation devices include: <br />1. Smoke detectors <br />2. Manual pull stations <br />3. Heat detectors <br /> <br />o. Annunciate initiation devices utilizing annunciation contacts on box circuit module in <br />control panel and not from individual device contacts unless otherwise noted on <br />drawings. When the control panel alarm silence switch is used on an initiation device <br />alarm, the system will maintain a trouble signal on the control panel, and continue to <br />light a lamp at the annunciator identifying appropriate initiation device zone until <br />problem is corrected. <br /> <br />H. With the exception of manual pull stations, annunciate all initiation devices utilizing <br />annunciation contacts on box circuit module in control panel and not from individual <br />device contacts. Annm1ciate manual pull stations individually from annunciation <br />contacts on each devic~. When the control panel alarm silence switch is used on an <br />initiation device alarm, I the system will maintain a trouble signal on the control panel, <br /> <br />July 12, 2000 <br />November 22, 2000 <br /> <br />16721 - 4 <br /> <br />99087.00 <br />Revision No.5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.