<br />conversion.can cause problems when the release of fumigant removes enough
<br />heat from the air to cause the air temperature to drop below its Dew Point
<br />temperature The amount 01 moisture a parcel of air can hold is dependent upon
<br />its temperaturE:.. The De", Point temperature for a parcel of air is the lemperature
<br />at which Illat air is holding as much moisture as it can hold If the temperature of
<br />air la11s below its Dew Point temperature, fog can form and moisture can condense
<br />from the air onto nearby surfaces if the temperature 01 these surfaces is low
<br />enough. The higher the percent relative humidity and the lower the temperature of
<br />surfaces in the fumigated space before Ihe introduction of fumigant, the greater the
<br />chance fog will form in the air and/or condensation will form on surfaces.
<br />Condensation can damage surfaces it forms on if they are sensitive to the
<br />presence of moisture.
<br />The conversion of the fumigant from liquid to gas normally occurs almost
<br />instantaneously when it is released into the fumigated space, however it is possible
<br />that, based on the circumstances, some fumigant will remain in its liquid form for a
<br />short period of time after it has been released. This can be a problem if this super-
<br />cooled liquid fumigant is deposited onto surfaces that can be damaged by its
<br />presence, however brief.
<br />Care must be taken to reduce the chances that moisture is condensed from the air
<br />within the fumigated space during fumigant application or that unconverted liquid
<br />fumigant is present within the fumigant space long enough to come to rest on
<br />surfaces. One way to accomplish both of these is to maximize the amount of air
<br />into whichlhe fumigant is released. The greater the number of 'units' of air used to
<br />vaporize each 'unit' of fumigant, the less heat that must be removed from each
<br />'unit" of .tir during the conversion process. This reduces the possibility that the
<br />capacity of tfle air into which the fumigant is released to hold water or fumigant will
<br />be ellCeeded. Increase the volume of air into which the fumigant is released, and
<br />thereby maximize the rate of fumigant vaporization from liquid to gas, by situating
<br />the discharge end of the fumigant shooting tube on the positive pressure side of an
<br />operating fan (blast side) located within a large open area of the fumigated space.
<br />The air movement capacity at the fan should be at least 1,000 cubic feet per minute
<br />for each pound of ZYTHOR released per minute.
<br />Using a small inside diameter shooting tube (1/8 inch) can also reduce the chances
<br />of un-vaporized fumigant coming to rest on surfaces within the fumigated space.
<br />To further protect against the effects of un-vaporized fumigant on surfaces, it is
<br />recommended that protective sheeting, such as polyethylene plastic, be placed on
<br />the ffoors in the vicinity of any fumigant release point. In order to prevent
<br />damage, do not apply fumigant directly to any surface.
<br />Special care should be taken when the percent relative humidity of the air within
<br />the fumigated space is high (the amount of moisture in the air is high compared to
<br />the total amount it can hold). If necessary delay the fumigation until conditions are
<br />more favorable such as when the relative humidity within the structure to be
<br />fumigated is lower.
<br />ZYTHOR RELEASE
<br />Before introducing the fumigant, verify that all required safety equipment is
<br />available and in good working order. Position the ZYTHOR cylinder(s) outside the
<br />space to be fumigated. 00 not connect cylinders to introduction equipment until all
<br />fumigation warning signs have been posted and the space to be fumigated is clear
<br />of persons, non-target animals and is properfy secured.
<br />Release the ZYTHOR from outside the fumigated space Wear splash resistant
<br />goggles or full face shield for eye protection during inlroduction of fumigant or when
<br />working around any lines containing fumigant under pressure. Do not wear gloves
<br />or rubber boots.
<br />
<br />AERATION AND CLEARANCE
<br />
<br />Aer1ltlon
<br />The final step in using ZYTHOR is to remove it from within the fumigated space
<br />(aeration) an<! to confirm its absence from the fumigated space after the completion
<br />of the aeration process (clearance). Aeration of ZYTHOR from a fumigated space
<br />involves actively exhausting and/or allowing the ZYTHOR to dissipate from the
<br />fumigated'. space out into the atmosphere. Clearance involves sampling the air
<br />willlin the fumigated space with an approved and property calibrated Low Fumigant
<br />Level Detection Device untit readings given by the detection device indicate that
<br />fumigant is ria longer present above 1 ppm within the breathing zones of any room
<br />of the fumigated space. Only when certain periods of lime (see Aeration
<br />Procedures below) have elapsed after the initiation 01 the aeration process and the
<br />Ievet of fumigant remaining is confirmed at the end of tl10se time periods to no
<br />longer exceed 1 ppm can final clearance for re-occupancy be given.
<br />Respiratory Protection Requirements During Aeration and
<br />Clearance
<br />The processes of aeration and clearance of the fumigated space require entry into
<br />the fumigated space while the level of ZYTHOR in the air within the fumigated
<br />space still exceeds 1 ppm All persons entering and/or remaining inside the
<br />fumigated space between the time of initial application 01 ZYTHOR to the fumigated
<br />space and final clearance of the fumigated space must adhere to the requirements
<br />of the Respiratory Protection, Respiratory Protection Devices and Low Fumigant
<br />Levet Detection Devices sections 01 this label.
<br />Aeration Procedures
<br />There are two approved procedures for aeration The aeration procedure used lor a
<br />lumlgated space is based on tile total amount of ZYTHOR per tllousand cubic feet
<br />that was released within the fumigated space during the exposure period. All
<br />structures into which a total 01 more tllan 16 ounces 01 ZYTHOR per thousand
<br />cubic leet ollumlgated space has been released during the Exposure Period must
<br />be aerated using Aeration Procedure 2. All other lumig3ted spaces can be aerated
<br />using either Aeration Procedure 1 or Aeration Procedure 2
<br />
<br />Aeration Procedure 1 - Applied Dose 16 oz/1000 cubic feet or less
<br />These steps must be completed in sequence.
<br />Step (1): Aerate the fumigated space with all operable windows and doors open,
<br />aided by the use of 1 or more fans, for a minimum of 1 hour. All of the fans used
<br />shall, in total, be capable of displacing at least 5,000 cubic feet of air per minute.
<br />The fans may be turned off for the remainder of the aeration period if desired.
<br />Step (2): Secure fumigated space and do not allow reentry for a minimum of 6
<br />110urs from the start of the aeration process (first opening of the seal). During this
<br />time, the fumigated space must remain posted.
<br />Step (3): After the minimum 6 hour waiting period, measure the concentration of
<br />ZYTHOR in the breathing zones of each room of the fumigated space using an
<br />approved and properly calibrated Low Fumigant Level Detection Device. If a
<br />concentration 01 ZYTHOR greater than 1 ppm is detected, ventilate the fumigated
<br />space by opening operable doors and windows for at least 10 minutes. Fumigated
<br />space may be cleared for re-occupancy when the concentration of ZYTHOR as
<br />measured with an approved and properfy calibrated Low Fumigant Level Detection
<br />Device is determined to be 1 ppm or less.
<br />Aeration Procedure 2 - Applied Dose More Than 16 oz/1000 cubic
<br />feet
<br />These steps must be completed in sequence,
<br />Step (1): Aerate the fumigated space with all operabfe windows and doors open,
<br />aided by the use of 1 or more fans, for a minimum of 1 hour. All of the fans used
<br />shall, in total, be capable of displacing at least 5,000 cubic feet of air per minute.
<br />The fans may be turned off for the remainder of the aeration period if desired.
<br />Step (2): Secure the fumigated space and do not allow reentry for a minimum of 8
<br />hours Irom the start of the aeration process (first opening of the seal). During this
<br />time, the fumigated space must remain posted.
<br />Step (3): After the minimum 8 hour waiting period, measure the concentration of
<br />ZYTHOR in the breathing zones of each room of the fumigated space using an
<br />approved and properly calibrated Low Fumigant Level Detection Device. If a
<br />concentration of ZYTHOR greater than 1 ppm is detected, ventilate the fumigated
<br />space by opening operable doors and window for at least 10 minutes. Fumigated
<br />space may be cleared for re-occupancy when the concentration of ZYTHOR as
<br />measured with an approved and properly calibrated Low Fumigant Level Detection
<br />Device is determined to be 1 ppm or less.
<br />Final Clearance and Re-occupancy
<br />Do not reoccupy fumigated space, i.e., structure, ship, vehicle or chamber, or move
<br />fumigated vehicles until aeration is complete and clearance has been given.
<br />Warning signs must remain posted until aeration is completed and final clearance
<br />for re-occupancy is given.
<br />
<br />TERMS AND CONDITIONS OF USE
<br />
<br />II terms of the following Warranty Disclaimer, Inherent Risks of Use or Limitation of
<br />Remedies are not acceptable, return unopened package at once to the seller for a
<br />full refund of the purchase price paid. Otherwise, use by the buyer or any other
<br />user constitutes acceptance of the terms under Warranty Disclaimer, Inherent
<br />Risks of Use and Limitation of Remedies.
<br />
<br />WARRANTY DISCLAIMER
<br />
<br />ENSYSTEX II warrants that this product conforms to the chemical description on
<br />the label and that it is reasonably fit for the purposes stated on the label when used
<br />in strict accordance with the directions for use, subject to the inherent risks set forth
<br />below. ENSYSTEX II MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY
<br />OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR
<br />ANY OTHER EXPRESS OR IMPLIED WARRANTY.
<br />
<br />INHERENT RISKS OF USE
<br />
<br />lt is impossible to eliminate all risks associated with use of this product. Lack of
<br />performance or other unintended consequences may result because 01 lactors
<br />such as use of the product contrary to the label directions or contrary to the dosage
<br />and/or exposure period recommendations 01 the Fumicalc, adverse conditions
<br />(such as unfavorable temperatures, high humidity, unfavorable soil conditions,
<br />excessive rainfall, etc.), abnormal conditions (such as excessive winds, tornadoes,
<br />hurricanes), presence of other materials, the manner of application or other factors,
<br />all of which are beyond the control of ENSYSTEX II or the seller. All such risks
<br />shall be assumed by the Buyer and User.
<br />
<br />LIMITATION OF REMEDIES
<br />
<br />The exclusive remedy lor losses or damages resulting Irom the use of this product
<br />(including claims based on contract, negligence, strict liability or other legal
<br />theories), shall be limited to, at ENSYSTEX II's election, one of the following:
<br />Refund 01 purchase price paid by the buyer or user for product bought or
<br />replacement of amount of product used.
<br />ENSYSTEX II shall not be liable for losses or damages resulting from handling or
<br />use of this product unless ENSYSTEX II is promptly notified of such loss or
<br />damage in writing In no case shall ENSYSTEX II be liable for consequential or
<br />incidental damages or losses even if ENSYSTEX II knew 01, was advised of, or
<br />sllould have been aware 01 the possibility of such damages.
<br />The terms of the Terms and Conditions of Use, Warranty Disclaimer, Inherent
<br />Risks 01 Use and this Limitation 01 Remedies cannot be varied by any written or
<br />verbal statements or agreements. No employee or sales agent of ENSYSTEX II or
<br />the seller is authorized to vary or exceed the terms of the Warranty Disclaimer or
<br />this Limitation of Remedies in any manner.