<br />conversion.can cause problems when the release of fumigant removes enough <br />heat from the air to cause the air temperature to drop below its Dew Point <br />temperature The amount 01 moisture a parcel of air can hold is dependent upon <br />its temperaturE:.. The De", Point temperature for a parcel of air is the lemperature <br />at which Illat air is holding as much moisture as it can hold If the temperature of <br />air la11s below its Dew Point temperature, fog can form and moisture can condense <br />from the air onto nearby surfaces if the temperature 01 these surfaces is low <br />enough. The higher the percent relative humidity and the lower the temperature of <br />surfaces in the fumigated space before Ihe introduction of fumigant, the greater the <br />chance fog will form in the air and/or condensation will form on surfaces. <br />Condensation can damage surfaces it forms on if they are sensitive to the <br />presence of moisture. <br />The conversion of the fumigant from liquid to gas normally occurs almost <br />instantaneously when it is released into the fumigated space, however it is possible <br />that, based on the circumstances, some fumigant will remain in its liquid form for a <br />short period of time after it has been released. This can be a problem if this super- <br />cooled liquid fumigant is deposited onto surfaces that can be damaged by its <br />presence, however brief. <br />Care must be taken to reduce the chances that moisture is condensed from the air <br />within the fumigated space during fumigant application or that unconverted liquid <br />fumigant is present within the fumigant space long enough to come to rest on <br />surfaces. One way to accomplish both of these is to maximize the amount of air <br />into whichlhe fumigant is released. The greater the number of 'units' of air used to <br />vaporize each 'unit' of fumigant, the less heat that must be removed from each <br />'unit" of .tir during the conversion process. This reduces the possibility that the <br />capacity of tfle air into which the fumigant is released to hold water or fumigant will <br />be ellCeeded. Increase the volume of air into which the fumigant is released, and <br />thereby maximize the rate of fumigant vaporization from liquid to gas, by situating <br />the discharge end of the fumigant shooting tube on the positive pressure side of an <br />operating fan (blast side) located within a large open area of the fumigated space. <br />The air movement capacity at the fan should be at least 1,000 cubic feet per minute <br />for each pound of ZYTHOR released per minute. <br />Using a small inside diameter shooting tube (1/8 inch) can also reduce the chances <br />of un-vaporized fumigant coming to rest on surfaces within the fumigated space. <br />To further protect against the effects of un-vaporized fumigant on surfaces, it is <br />recommended that protective sheeting, such as polyethylene plastic, be placed on <br />the ffoors in the vicinity of any fumigant release point. In order to prevent <br />damage, do not apply fumigant directly to any surface. <br />Special care should be taken when the percent relative humidity of the air within <br />the fumigated space is high (the amount of moisture in the air is high compared to <br />the total amount it can hold). If necessary delay the fumigation until conditions are <br />more favorable such as when the relative humidity within the structure to be <br />fumigated is lower. <br />ZYTHOR RELEASE <br />Before introducing the fumigant, verify that all required safety equipment is <br />available and in good working order. Position the ZYTHOR cylinder(s) outside the <br />space to be fumigated. 00 not connect cylinders to introduction equipment until all <br />fumigation warning signs have been posted and the space to be fumigated is clear <br />of persons, non-target animals and is properfy secured. <br />Release the ZYTHOR from outside the fumigated space Wear splash resistant <br />goggles or full face shield for eye protection during inlroduction of fumigant or when <br />working around any lines containing fumigant under pressure. Do not wear gloves <br />or rubber boots. <br /> <br />AERATION AND CLEARANCE <br /> <br />Aer1ltlon <br />The final step in using ZYTHOR is to remove it from within the fumigated space <br />(aeration) an<! to confirm its absence from the fumigated space after the completion <br />of the aeration process (clearance). Aeration of ZYTHOR from a fumigated space <br />involves actively exhausting and/or allowing the ZYTHOR to dissipate from the <br />fumigated'. space out into the atmosphere. Clearance involves sampling the air <br />willlin the fumigated space with an approved and property calibrated Low Fumigant <br />Level Detection Device untit readings given by the detection device indicate that <br />fumigant is ria longer present above 1 ppm within the breathing zones of any room <br />of the fumigated space. Only when certain periods of lime (see Aeration <br />Procedures below) have elapsed after the initiation 01 the aeration process and the <br />Ievet of fumigant remaining is confirmed at the end of tl10se time periods to no <br />longer exceed 1 ppm can final clearance for re-occupancy be given. <br />Respiratory Protection Requirements During Aeration and <br />Clearance <br />The processes of aeration and clearance of the fumigated space require entry into <br />the fumigated space while the level of ZYTHOR in the air within the fumigated <br />space still exceeds 1 ppm All persons entering and/or remaining inside the <br />fumigated space between the time of initial application 01 ZYTHOR to the fumigated <br />space and final clearance of the fumigated space must adhere to the requirements <br />of the Respiratory Protection, Respiratory Protection Devices and Low Fumigant <br />Levet Detection Devices sections 01 this label. <br />Aeration Procedures <br />There are two approved procedures for aeration The aeration procedure used lor a <br />lumlgated space is based on tile total amount of ZYTHOR per tllousand cubic feet <br />that was released within the fumigated space during the exposure period. All <br />structures into which a total 01 more tllan 16 ounces 01 ZYTHOR per thousand <br />cubic leet ollumlgated space has been released during the Exposure Period must <br />be aerated using Aeration Procedure 2. All other lumig3ted spaces can be aerated <br />using either Aeration Procedure 1 or Aeration Procedure 2 <br /> <br />Aeration Procedure 1 - Applied Dose 16 oz/1000 cubic feet or less <br />These steps must be completed in sequence. <br />Step (1): Aerate the fumigated space with all operable windows and doors open, <br />aided by the use of 1 or more fans, for a minimum of 1 hour. All of the fans used <br />shall, in total, be capable of displacing at least 5,000 cubic feet of air per minute. <br />The fans may be turned off for the remainder of the aeration period if desired. <br />Step (2): Secure fumigated space and do not allow reentry for a minimum of 6 <br />110urs from the start of the aeration process (first opening of the seal). During this <br />time, the fumigated space must remain posted. <br />Step (3): After the minimum 6 hour waiting period, measure the concentration of <br />ZYTHOR in the breathing zones of each room of the fumigated space using an <br />approved and properly calibrated Low Fumigant Level Detection Device. If a <br />concentration 01 ZYTHOR greater than 1 ppm is detected, ventilate the fumigated <br />space by opening operable doors and windows for at least 10 minutes. Fumigated <br />space may be cleared for re-occupancy when the concentration of ZYTHOR as <br />measured with an approved and properfy calibrated Low Fumigant Level Detection <br />Device is determined to be 1 ppm or less. <br />Aeration Procedure 2 - Applied Dose More Than 16 oz/1000 cubic <br />feet <br />These steps must be completed in sequence, <br />Step (1): Aerate the fumigated space with all operabfe windows and doors open, <br />aided by the use of 1 or more fans, for a minimum of 1 hour. All of the fans used <br />shall, in total, be capable of displacing at least 5,000 cubic feet of air per minute. <br />The fans may be turned off for the remainder of the aeration period if desired. <br />Step (2): Secure the fumigated space and do not allow reentry for a minimum of 8 <br />hours Irom the start of the aeration process (first opening of the seal). During this <br />time, the fumigated space must remain posted. <br />Step (3): After the minimum 8 hour waiting period, measure the concentration of <br />ZYTHOR in the breathing zones of each room of the fumigated space using an <br />approved and properly calibrated Low Fumigant Level Detection Device. If a <br />concentration of ZYTHOR greater than 1 ppm is detected, ventilate the fumigated <br />space by opening operable doors and window for at least 10 minutes. Fumigated <br />space may be cleared for re-occupancy when the concentration of ZYTHOR as <br />measured with an approved and properly calibrated Low Fumigant Level Detection <br />Device is determined to be 1 ppm or less. <br />Final Clearance and Re-occupancy <br />Do not reoccupy fumigated space, i.e., structure, ship, vehicle or chamber, or move <br />fumigated vehicles until aeration is complete and clearance has been given. <br />Warning signs must remain posted until aeration is completed and final clearance <br />for re-occupancy is given. <br /> <br />TERMS AND CONDITIONS OF USE <br /> <br />II terms of the following Warranty Disclaimer, Inherent Risks of Use or Limitation of <br />Remedies are not acceptable, return unopened package at once to the seller for a <br />full refund of the purchase price paid. Otherwise, use by the buyer or any other <br />user constitutes acceptance of the terms under Warranty Disclaimer, Inherent <br />Risks of Use and Limitation of Remedies. <br /> <br />WARRANTY DISCLAIMER <br /> <br />ENSYSTEX II warrants that this product conforms to the chemical description on <br />the label and that it is reasonably fit for the purposes stated on the label when used <br />in strict accordance with the directions for use, subject to the inherent risks set forth <br />below. ENSYSTEX II MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY <br />OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR <br />ANY OTHER EXPRESS OR IMPLIED WARRANTY. <br /> <br />INHERENT RISKS OF USE <br /> <br />lt is impossible to eliminate all risks associated with use of this product. Lack of <br />performance or other unintended consequences may result because 01 lactors <br />such as use of the product contrary to the label directions or contrary to the dosage <br />and/or exposure period recommendations 01 the Fumicalc, adverse conditions <br />(such as unfavorable temperatures, high humidity, unfavorable soil conditions, <br />excessive rainfall, etc.), abnormal conditions (such as excessive winds, tornadoes, <br />hurricanes), presence of other materials, the manner of application or other factors, <br />all of which are beyond the control of ENSYSTEX II or the seller. All such risks <br />shall be assumed by the Buyer and User. <br /> <br />LIMITATION OF REMEDIES <br /> <br />The exclusive remedy lor losses or damages resulting Irom the use of this product <br />(including claims based on contract, negligence, strict liability or other legal <br />theories), shall be limited to, at ENSYSTEX II's election, one of the following: <br />Refund 01 purchase price paid by the buyer or user for product bought or <br />replacement of amount of product used. <br />ENSYSTEX II shall not be liable for losses or damages resulting from handling or <br />use of this product unless ENSYSTEX II is promptly notified of such loss or <br />damage in writing In no case shall ENSYSTEX II be liable for consequential or <br />incidental damages or losses even if ENSYSTEX II knew 01, was advised of, or <br />sllould have been aware 01 the possibility of such damages. <br />The terms of the Terms and Conditions of Use, Warranty Disclaimer, Inherent <br />Risks 01 Use and this Limitation 01 Remedies cannot be varied by any written or <br />verbal statements or agreements. No employee or sales agent of ENSYSTEX II or <br />the seller is authorized to vary or exceed the terms of the Warranty Disclaimer or <br />this Limitation of Remedies in any manner. <br /> <br />5 <br />