DN- 7087:A • J -70
<br /> SpectrAlert Advance
<br /> 0 e
<br /> Selectable Output N OT I F I E R
<br /> Notification Appliances by Honeywell
<br /> Audio/Visual Devices
<br /> General 7887pho1.pg 7O87q,
<br /> System Sensor® SpectrAlert® Advance selectable- output
<br /> w ,
<br /> horns, strobes and horn /strobes are rich with features guaran- .;:, a .
<br /> teed to cut installation times and maximize profits. The SpectrA-
<br /> lert Advance series of notification appliances is designed to _- _-mac,,
<br /> simplify your installations, with features such as: plug -in .. . t.,0,....x.
<br /> 4. „
<br /> designs, instant feedback messages to ensure correct installa- '
<br /> tion of individual devices, and eleven field- selectable candela : ; s w ' "'
<br /> -
<br /> settings for wall and ceiling strobes and horn /strobes. ` ` _ " . 1 ' �‘' 'F '' ",
<br /> More specifically, when installing Advance products, first attach Indoor Ceiling Horn/Strobe Outdoor Ceiling Strobe
<br /> a universal mounting plate to a four -inch square, four -inch octa- 70e7phoa.pQ 7087ph,4.pa
<br /> ant
<br /> gon, or double-gang junction box. The two -wire mounting plate � _� `° } ,t A
<br /> ;
<br /> attaches to a single -gang junction box. ' r. 4 { A
<br /> Then, connect the notification appliance circuit wiring to the f ` . ., . ,
<br /> SEMS terminals on the mounting plate. i. v ;t i r; , , •e
<br /> Finally, attach the horn, strobe, or horn /strobe to the mounting c t "` r r r : - ' .�
<br /> plate by inserting the product's tabs in the mounting plate's i � k
<br /> grooves. The device will rotate into position, locking the prod - c 'i"a : ..
<br /> uct's pins into the mounting plate's terminals. The device will" ^ ° ° y "`
<br /> temporarily hold in place with a catch until it is secured with a Indoor Wall Horn/Strobe Indoor Ceiling Strobe
<br /> captured mounting screw. 7087pho5.pg 7087pho8.pg
<br /> SpectrAlert Advance products allow you to choose: t
<br /> • 12 or 24 volts. J ' $.:#1",:
<br /> • At 24 volts, 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, or e r + r ,
<br /> 185 candela by way of a rear - mounted slide switch and front V e ' e ' s
<br /> G
<br /> viewing window. F` ,
<br /> • Horn tones and volume by way of a rotary switch. i x;
<br /> • The SpectrAlert Advance series includes outdoor notification t b
<br /> appliances. Outdoor strobes and horn /strobes (two -wire and Indoor Wall Horn Outdoor Wall Strobe
<br /> four -wire) are available for wall or ceiling. Outdoor horns are
<br /> available for wall only. All System Sensor outdoor products • Minimal intrusion into the backbox.
<br /> are rated between —40 °F and 151 °F (-40 °C and 66 °C) in wet • Horn rated at 88+ dbA at 16 volts.
<br /> or dry applications.
<br /> Models available: • Rotary switch for tone selection.
<br /> • Three horn volume settings.
<br /> • Indoor wall- mount: horn, strobe, 2 -wire horn /strobe, 4 -wire
<br /> horn /strobe. • Electrically compatible with existing SpectrAlert products.
<br /> • Indoor ceiling- mount: strobe, 2 -wire horn /strobe, 4 -wire horn/
<br /> strobe. Engineering Specifications
<br /> • Outdoor wall- mount: horn, strobe, 2 -wire horn /strobe, 4 -wire SpectrAlert Advance horns, strobes, and horn /strobes shall
<br /> horn /strobe. mount to a standard 4.0" x 4.0" x 1.5" (10.16 x 10.16 x 3.81 cm)
<br /> • Outdoor ceiling- mount: strobe, 2 -wire horn /strobe, 4 -wire backbox, 4.0" (10.16 cm) octagonal backbox, or a double -gang
<br /> horn /strobe. backbox. Two -wire products shall also mount to a single -gang
<br /> 2.0" x 4.0" x 1.875" (5.08 x 10.16 x 4.763 cm) backbox. A uni-
<br /> Features versal mounting plate shall be used for mounting ceiling and
<br /> wall products. The notification appliance circuit wiring shall ter-
<br /> • Plug -in design. minate at the universal mounting plate. Also, SpectrAlert
<br /> • Same mounting plate for wall- and ceiling -mount units. Advance products, when used with the Sync•CircuitTM' Module
<br /> • Shorting spring on mounting plate for continuity check before accessory, shall be powered from a non -coded notification appli-
<br /> installation. ance circuit output and shall operate on a nominal 12 or 24
<br /> volts. When used with the Sync•Circuit Module, 12 -volt rated
<br /> • Captive mounting screw. notification appliance circuit outputs shall operate between 9
<br /> • Tamper- resistance capability. and 17.5 volts; 24 -volt rated notification appliance circuit outputs
<br /> • Field- selectable candela settings on wall and ceiling units: shall operate between 17 and 33 volts. Indoor SpectrAlert
<br /> 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, 185. Advance products shall operate between 32 °F and 120 °F (0 °C
<br /> • Automatic selection of 12 or 24 volt operation at 15 and 15/75 and 49 °C) from a regulated DC, or full - wave - rectified, unfiltered
<br /> candela. power supply. Strobes and horn /strobes shall have field- select-
<br /> • Outdoor wall and ceiling products. able candela settings including 15, 15/75, 30, 75, 95, 110, 115,
<br /> • Outdoor products rated from —40 °F and 151°F (-40 °C and 135, 150, 177, 185.
<br /> 66 °C).
<br /> DN- 7087:A • 10/18/06 — Page 1 of 4