My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-11786
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-11786
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/9/2012 9:01:27 AM
Creation date
2/9/2012 9:00:05 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-11786
Building Department - Name
TOWNVIEW RETAIL LLC
Address
7326 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
dn-6999:a•A1-350 <br /> Mon't r Modules � N OT 1 F 1 E R <br /> NMM-1�NMM-100P NZM-100 and � <br /> —� � � � <br /> NDM-100 for FireWarden Systems by Honeywel{ <br /> General <br /> Four different monitor modules are available for Notifier's Fire- f� � � C� <br /> Warden-series intelligent control panels to suit a variety of �J U <br /> applications. Monitor modules are used to supervise a circuit <br /> of dry-contact input devices, such as conventional heat detec- p� 9 ,e� o <br /> tors and puli stations, or monitor and power a circuit of two- �� e���_ �� <br /> wire smoke detectors (NZM-100) _ �,�„�0,5+�' 2 NMM-100 and NZM-100 <br /> a Ql6y <br /> NMM-100 is a standard-sized module (typically mounts to a 4" �� s 3 <br /> [10.16 cm] square box) that supervises either a Class A(Style S a <br /> D) or Ciass B(Style B) circuit of dry-contact input devices. LOOP ^°°REu <br /> o � NMM-100P is a miniature monitor module (a mere 1.3° (3.302 � � Q <br /> cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D) used to � <br /> supervise a Class B(Style B) circuit of dry-contact input <br /> devices. Its compact design aliows the NMM-100P to often be � � O C� <br /> mounted in a single-gang box behind the device it monitors. U <br /> NZM-100 is a standard-sized module used to monitor and y � o � <br /> supervise compatible two-wire, 24 volt, smoke detectors on a detail of NDM-100 - note : r <br /> Class A(Sryle D) or Class B(Style B) circuit. "ones" addresses are 0 2 8= , a � 3 <br /> � e �� , 2 g <br /> NDM-100 is a standard-sized dual monitor module used to 4, 6, 8 only � 6 6 � 3 <br /> monitor and supervise two independent two-wire Style B s�: a <br /> (Class B) dry-contact initiating device circuits (IDCs) at two �° <br /> LOOP ADDRESS <br /> separate, consecutive addresses in intelligent, two-wire systems. o <br /> Q O O � <br /> —� NMM-100 Monitor Module <br /> • Built-in type identification automatically identifies this device <br /> as a monitor module to the control panel. <br /> • Powered directly by two-wire SLC loop. No additional power NMM-100 OPERATION <br /> required. Each NMM-100 uses one of the available module addresses <br /> • High noise (EMF/RFI) immunity. on an SLC loop. It responds to regular polls from the control <br /> • SEMS screws with clamping plates for ease of wiring. panel and reports its rype and the status (open/normal/short) <br /> of its Initiating Device Circuit (IDC). A fiashing LED indicates <br /> • Direct-dial entry of address: 01 — 159 on NFW-100, 01 — 99 that the module is in communication with the control panel. <br /> on NFW-50. The LED latches steady on alarm (subject to current limita- <br /> • LED flashes during normal operation and latches on steady tions on the loop). <br /> to indicate alarm. <br /> The NMM-100 Monitor Module is intended for use in intelli- NMM-100 SPEC/FICATIONS <br /> gent, two-wire systems, where the individual address of each Nominal operating voltage: 15 to 32 VDC. <br /> module is selected using the built-in rotary switches. It pro- Maximum current draw• 5.1 mA (LED on). <br /> vides either a two-wire or four-wire fault-tolerant Initiating � <br /> Device Circuit (IDC) for normally-open-contact fire alarm and Maximum operating current: 375 NA (LED flashing). <br /> supervisory devices. The module has a panel-controiled LED Maximum IDC wiring resistance: 1,500 ohms. <br /> indicator. <br /> EOL resistance: 47K ohms. <br /> NMM-100 APPL/CATIONS Temperature range: 32°F to 120°F (0°C to 49°C). <br /> Use to monitor a zone of four-wire smoke detectors, manual Humidity range: 10% to 93% noncondensing. <br /> fire alarm pull stations, waterfiow devices, or other normally- <br /> open dry-contact alarm activation devices. May also be used Dimensions: 4.5" (11.43 cm) high x 4° (10.16 cm) wide x <br /> to monitor normally-open supervisory devices with special 1•25` (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x <br /> supervisory indication at the control panel. Monitored circuit 2.125" (5.398 cm) deep box. <br /> may be wired as an NFPA Style B(Class B) or Sryle D(Clas <br /> A) Initiating Device Circuit. A 47K ohm End-of-Line Re stsm� NMM-1 OOP Mini Monitor Module <br /> (provided) terminates the Style B circuit. No resistor is '. guilt-in type identification automatically identifies this device <br /> required for supervision of the Style D circuit. as a monitor module to the panel. <br /> • Powered directly by two-wire FACP. No additional power <br /> required. <br /> • High noise (EMF/RFI) immuniry. <br /> • Tinned, stripped leads for ease of wiring. <br /> dn-6999:a • 04/28/OS — Page 1 of 6 <br /> P. 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.