My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
11-12206
Zephyrhills
>
Building Department
>
Permits
>
2011
>
11-12206
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2012 1:43:01 PM
Creation date
5/10/2012 1:42:58 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
11-12206
Building Department - Name
GARCIA,ALBERTO
Address
5125 18TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
[ ���� ��.' � <br /> 6.6 UnderRoof Tile Underlayment: <br /> 6 6 1 UnderRoof Tile Underlayment shall not be left exposed for longer than 180-days after <br /> installation. <br /> 6 6 2 UnderRoof Tile Underlayment shall be installed in compliance with the requirements for ASTM <br /> D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be <br /> installed. <br /> 6 6 3 For tile roof installations governed by the FRSA/TRI 07320/8-05 Installation Manual, Fourth <br /> Edition, use is limited to• <br /> � System 1, Option 5 or 6, Section 3.02E or F <br /> � System 2, Option 4 or 5, Section 3.02D or E <br /> 6.6 4 The minimum and maximum roof slopes are 2:12 and 12•12, respectively. Back-nailing is <br /> required when slope is 4:12 or greater. Back-nailing shall consist of minirrium 1-inch square or <br /> round cap nails spaced 6" o.c. within 4-inch side laps. <br /> 6.6.5 Prior to removal of release film, align sheets properly starting at the low-point of the roof <br /> (eave) with the selvage edge upslope and for minimum 2-inch overhang at eaves and rakes. <br /> Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch <br /> over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to <br /> substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load <br /> requirements. Install 1/8-inch troweling of LeakBusterT"' Matrix�"' 201 Premium SBS Flashing <br /> Cement over drip edge <br /> 6 6 6 Continue upslope in a similar manner, maintaining minimum 4-inch side-laps and minimum 6- <br /> inch end-laps Ensure all end laps are staggered at least 3-feet apart. End laps shall be sealed <br /> with a 1/16` to 1/8� inch thick trowel application of LeakBusterT"' MatrixT'" 201 Premium SBS <br /> Flashing Cement. <br /> 6.6.7 Use a hand roller to firmly bond side and end laps. <br /> 6.7 UnderRoof 2 Tile Underlayment: <br /> 6 7.1 UnderRoof 2 Tile Underlayment shall not be left exposed for longer than 180-days after <br /> installation <br /> 6 7 2 UnderRoof 2 Tile Underlayment shall be installed in compliance with the re�quirements for ASTM <br /> D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be <br /> installed UnderRoof 2 is not for use under metal roofs <br /> 6.7 3 For tile roof installations governed by the FRSA/TRI 07320/8-05 Instailation Manual, Fourth <br /> Edition, use is limited to. <br /> : System 1, Option 5 or 6 <br /> > System 2, Option 4 or 5 <br /> .� System 4, Underlayment Option "A", Option 4 or 5(Polyfoam Polyset Only) <br /> > System 4, Underlayment Option '�B", Option 3 or 4(Polyfoam Polyset Only) <br /> 6 7 4 The minimum and maximum roof slopes are 2:12 and 12 12, respectively Back-nailing is <br /> required when slope is 4 12 or greater Back-nailing shall consist of minirnum 1-inch square or <br /> round cap nails spaced 12" o.c. within 4-inch side laps. <br /> Exterior Research and Design, LLC. Evaluation Report 01506.04.08 <br /> Certificate of Authorization #9503 FL10626 <br /> Date of Issuance: 04/25/2008 <br /> Page 6 of 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.