My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
12-12786
Zephyrhills
>
Building Department
>
Permits
>
2012
>
12-12786
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2013 12:43:21 PM
Creation date
1/28/2013 12:43:17 PM
Metadata
Fields
Template:
Building Department
Company Name
CHILI'S BAR & GRILL
Building Department - Doc Type
Permit
Permit #
12-12786
Building Department - Name
CHILI'S BAR & GRILL
Address
7643 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, , SECTiON tV—SYSTEM DESIGN <br /> ' UL EX. 5174 10-31-97 Page 4-13 <br /> MECHANICAL GAS VALVE REQUIREMENTS ELECTRICAL GAS VALVE REQUIREMENTS <br /> An Ansul orAnsul approved mechanical gas shut-off valve system A UL Listed electrically-operated gas shut-off valve can be <br /> can be attached to the PIRANHA system.The system works both attached to the PIRANHAsystem to provide an electrical means of <br /> mechanically and pneumatically by use of an air cylinder located shutting off the gas line at a predetermined point. If an electric gas <br /> inside the regulated release assembly Upon actuation of the fire shut-off valve is used in the system it must be attached with both <br /> suppression system,a pneumatically-operated air cylinder assem- an electric (snap-action) switch and a manual reset relay For <br /> bly will mechanically close the gas shut-off valve. more information on the types of electric (snap-action) switches, <br /> The total length of the cable for the mechanical gas valve must not refer to the Electrical Switch, Fieid Installation section. <br /> exceed 150 ft.(46 m).The maximum number of pulley elbows that AI� electrical connections should be performed by a QUALIFIED <br /> may be used is 20 ELECTRICIAN and in accordance with authority having jurisdiction. <br /> One pulley tee (Part No 15342) is aflowed per system. The following is a brief explanation of how the PIRANHA system <br /> Exception: When using a pulley tee, Part No 15342, the maxi- operates with an Electric Gas Shut-off Valve attached: <br /> mum length of wire rope to each gas valve (maximum of two gas With the regulated release cocked in the ready condition,the nor- <br /> valves) must not exceed 125 ft. (38 m) and the maximum number mally closed contacts in the snap-action switch allow current to <br /> of elbows must not exceed 18 flow to the manual reset relay. With the relay coil energized, nor- <br /> Parts that may be used for installation of a Mechanical Gas Shut- mally open contacts in the reset relay close, aliowing the solenoid <br /> off Valve are in the gas valve to be energized. <br /> Description Part No. Once the PIRANHA system is activated, the normally ciosed con- <br /> tacts in the snap-action switch will open, de-energizing the reset <br /> Gas Valve/Actuator 3/4 in.Assembly (Ansul)` 55598 relay This will, in turn, open the contacts in the relay which wil( <br /> Gas Valve/Actuator 1 in.Assembly (Ansul)" 55601 cause the gas valve to become de-energized and close <br /> Gas Valve/Actuator 1 1/4 in.Assembly(Ansul)' 55604 <br /> Gas Valve/Actuator 1 1/2 in.Assembly(Ansul)' 55607 The system must be re-armed and the "push to reseY' button on <br /> Gas Valve/Actuator 2 in.Assembly(Ansul)" 55610 the reset relay must be operated to reopen the gas valve. <br /> Gas Valve/Actuator 2 1/2 in.Assembly(ASCO)" 25937 It is important to note that a power failure or an electrical power <br /> Gas Valve/Actuator 3 in.Assembly(ASCO)' 25938 interruption will cause the gas valve to close even though the sys- <br /> Pulley Elbow" 423250 tem was not fired. <br /> Pulley Elbow" 415670 In either case,whether in a fired condition or when a ower failure <br /> Pulley Tee'�" 15342 has occurred, the manual reset relay and electric gas shut-off <br /> 1/16"Stainless Steel Cable 15821 or valve must be reset to resume a normal operating condition. For <br /> 50 ft. (15 m) or 500 ft. (152 m) roll 79653 resetting, refer to the "Recharge and Resetting Procedures" <br /> Oval Press-To-Crimp Sleeve 4596 section in this manual. <br /> Stop Sleeve (2) 26317 <br /> ' Assembly includes parts listed below: IQppl'OV1�S <br /> " Approved for 700°F(371°C)temperature areas. <br /> "' Used with two(2)ANSULAUTOMAN releases to operate one(1)mechanical gas valve. Al1SUI g8S VaIV@S IISt2CI Ifl tIIIS S@Ct1011 8C2 UL IISteCj a11CI$pP�OV@C� <br /> Air Cylinder Assembly 15733 for 110 VAC If more information is required, refer to the Gas and <br /> Air Cylinder 15521 Oil Equipment List of Underwriters Laboratories, Inc. under <br /> Tubing Assembly 15529 "Electrically Operated Valves Guide No. 440 A5" or consult Ansul <br /> Copper Tubing, 1/8 in 15525 Incorporated, Marinette,Wisconsin 54143-2542. <br /> Male Elbow 15523 If other gas valves are used, they shall be "UL listed electrically- <br /> Male Connector 15522 operated safety valves for natural or LP gas as required,of appro- <br /> Machine Screw(2) 15427 priate pressure and temperature rating, 110 VAC/60 Hz." The <br /> Hex Nut(2) 15527 information on temperature and type of gas that the valves are <br /> Lockwasher(2) 4141 suitable for may be found in the Gas and Oil Equipment List of <br /> Visual Inspection Seal (2) 197 Underwriters Laboratories, Inc. under "Electrically Operated <br /> All valves above are UL listed and approved.They may be mount- Valves Guide No. 440 A5" <br /> ed in any position. Pipe threads are type NPT Ambient operating The electrically operated gas valve must be of the type that needs <br /> temperature range of all valves is 32 °F to 130°F(0°C to 54°C) to be energized to remain open. <br /> The valves are not weatherproof and must be located indoors in Parts that may be used for installation of a 110 VAC Gas Shut-off <br /> areas approved by the"authority having jurisdiction." Valve are• <br /> Description Part No. <br /> Electric Solenoid Valve, 3/4 in. NPT" 13707 <br /> Electric Solenoid Valve, 1 in. NPT' 13708 <br /> Electric Solenoid Valve, 1 1/2 in. NPT* 13709 <br /> Electric Solenoid Valve, 2 in. NPT* 13710 <br /> Electric Solenoid Valve, 3 in. NPT* 17643 <br /> Manual Reset Relay(110 VAC) 14702 <br /> 'Vaives are normally closed when de-energized. <br />
The URL can be used to link to this page
Your browser does not support the video tag.