Laserfiche WebLink
LCD-160 Interface and Indicators Supervisory: Scroll/display a list of associated events. <br /> , The liquid crystal display is 40 characters wide and 16 lines Trouble: Scroll/display a list of associated events. <br /> deep, and displays all programming screens and other infor- Other Event: Scroll between prealarrci and disabled events. <br /> _ mation. The keypad is functional only when an entry is For complete information on key functions and effects on dif- <br /> requested by the system. Enter or change fields and issue ferent panels, refer to the LCD-160 Manual and panel manu- <br /> commands on the display by using the two types of keys on als. <br /> the keypad:fixed function and soft keys. <br /> Soft keys are the six keys to the right and left of the display. <br /> Fixed function keys are the ten keys labeled on the front of Use them to select commands that appear on the display for <br /> the LCD-160,operating at ali times on all screens unless oth- each different screen. Refer to the sr,reens in the LCD-160 <br /> erwise noted. With both an active command center and DCC Manual for descriptions of the applicable soft keys. <br /> enabled at the panel, Acknowledge, Signal Silence, System <br /> Reset, and Drili require permission before they can be pro- STATUS LED lNDICATORS <br /> cessed. Power (green) iiluminates when AC power is within normal <br /> Acknowledge: Press to respond to any event or trouble sig- operating limits. <br /> nai.If enabled,silences the LCD-160 piezo sounder.Sends an Fire Alarm(red)iHuminates when at least one fire alarm event <br /> acknowledge message to the panel. exists.It will flash if any of these events are unacknowledged. <br /> Signal Silence: Press to send a system silence command to pre-Alarm(red)illuminates when at least one pre-alarm event <br /> the panel, with the particular silencing action information exists.It will flash if any of these events are unacknowledged. <br /> stored at the FACP. Verification screen appears on networked <br /> displays. Security (blue)illuminates when at least one security event <br /> exists.It will flash if any of these events are unacknowledged. <br /> System Reset: Press to send a system reset command to <br /> the panel,with the particufar reset action information stored at Supervisory (yellow)illuminates when at least one supervi- <br /> the FACP.Verification screen appears on networked displays. sory event exists. It will flash if any of these events are unac- <br /> knowledged. <br /> Drill: Press (hold for two seconds) to activate all silenceable <br /> fire output circuits. System Trouble (yellow)illuminates when at least one trou- <br /> ble event exists. It will flash if any of these events are unac- <br /> Lamp Test: Press to test the LED indicators and the piezo,or knowledged. <br /> display firmware version numbers. <br /> Other Event(yellow)(future release). <br /> Fire Alarm: Scroli/dispiay a list of associated events. <br /> Security: Scroll/display a list of associated events. <br /> �J4 <br /> � � � . <br /> J3 � <br /> �� J1 <br /> LCD ��2 <br /> BACKLIGHT LC D�� �O KEY SWITCH <br /> J2 <br /> 1 d--h 2 <br /> ❑ o <br /> ❑ <br /> LCD o ° <br /> 0 <br /> 0 0 <br /> 0 <br /> 19 4°20 <br /> � � <br /> ouoaaou0000000a �} POWER <br /> IN <br /> 000u000000uou000� +24VDCOUT <br /> STATUS o �yi��nnnnnnnnmiun7 a �J COMMON IN TBZ <br /> LED11 � _ ° CoMMONOU7 <br /> = 3 � RDP <br /> MlCRO FAIL o � £ TB1 RoP+ <br /> �IAItlpItlI01111AMIIIIIItlIIJ RDP4 <br /> LED14 �00000000a000000°o�v' RDP— <br /> 000000a000uooaod RECElVE RDP— <br /> SW17� LED 12 REF <br /> TRANSMIT REF � <br /> LED 13 F�+RTM a <br /> Page 2 oi 4—DN-6940:A•12/01/06 <br />